Ammonia (5 mintues total ; 2 test bottles -still working yellow old is it)
-
make sure that you have the appropriate ammonia test solution bottles 2 Yellow bottles and color card freshwater ammonia
-
using the pipette fill the vial with water sample up to the black line
-
add 8 drop from ammonia test solutions bottle 1 lights yellow label to the vial
-
Add 8 drops from ammonia test solution bottle dark yellow label to the vial
-
Screw the cap on the vial and mix invert the volume multiple times to make sure the test solution drops are throughly mix
-
wait 5 minutes and compare the color of the sample to the freshwater ammonia color card
-
once you have recorded the results on the datasheet don't the contest in the waste water container
-
wash out container with distilled water